Table T14. Thermal conductivity measurements at Site 1088.
Core,
section, interval (cm) |
Depth (mbsf) |
Depth (mcd) |
TC (W/[m·K]) |
Start (s) |
Length (s) |
End (s) |
---|---|---|---|---|---|---|
177-1088A- | ||||||
1H-1, 50 | 0.50 | 2.88 | 0.831 | 83.0 | 25.0 | 108.0 |
1H-1, 50 | 0.50 | 2.88 | 0.825 | 94.5 | 25.5 | 120.0 |
177-1088B- | ||||||
4H-1, 75 | 25.25 | 25.25 | 1.000 | 111.0 | 25.0 | 136.0 |
5H-3, 75 | 37.75 | 37.75 | 1.102 | 78.0 | 26.0 | 104.0 |
5H-3, 75 | 37.75 | 37.75 | 1.144 | 27.0 | 26.5 | 53.5 |
6H-3, 75 | 47.25 | 47.25 | 1.070 | 94.5 | 25.5 | 120.0 |
7H-3, 75 | 56.75 | 56.75 | 1.162 | 102.0 | 25.0 | 127.0 |
7H-3, 75 | 56.75 | 56.75 | 1.147 | 124.0 | 25.5 | 149.5 |
8H-3, 75 | 66.25 | 66.25 | 1.176 | 51.5 | 25.0 | 76.5 |
8H-3, 75 | 66.25 | 66.25 | 1.155 | 61.0 | 26.5 | 87.5 |
9H-3, 75 | 75.75 | 75.75 | 1.094 | 110.5 | 26.5 | 137.0 |
9H-3, 75 | 75.75 | 75.75 | 1.115 | 91.0 | 25.0 | 116.0 |
10H-3, 75 | 85.25 | 85.25 | 1.119 | 74.0 | 25.0 | 99.0 |
10H-3, 75 | 85.25 | 85.25 | 1.119 | 116.5 | 28.5 | 145.0 |
11H-3, 75 | 94.75 | 94.75 | 1.156 | 79.5 | 30.5 | 110.0 |
11H-3, 75 | 94.75 | 94.75 | 1.172 | 49.5 | 25.0 | 74.5 |
12H-3, 75 | 104.25 | 104.25 | 1.209 | 121.0 | 25.0 | 146.0 |
12H-3, 75 | 104.25 | 104.25 | 1.148 | 77.5 | 40.0 | 117.5 |
13H-3, 75 | 113.75 | 113.75 | 1.159 | 95.0 | 25.0 | 120.0 |
13H-3, 75 | 113.75 | 113.75 | 1.206 | 25.0 | 28.0 | 53.0 |
14H-3, 75 | 123.25 | 123.25 | 1.161 | 111.5 | 25.5 | 137.0 |
14H-3, 75 | 123.25 | 123.25 | 1.180 | 68.5 | 26.5 | 95.0 |
14H-3, 75 | 123.25 | 123.25 | 1.133 | 114.0 | 25.0 | 139.0 |
177-1088C- | ||||||
2H-3, 75 | 128.05 | 126.19 | 1.169 | 107.0 | 25.0 | 132.0 |
2H-3, 75 | 128.05 | 126.19 | 1.214 | 53.0 | 29.5 | 82.5 |
3H-3, 75 | 137.55 | 135.69 | 1.143 | 120.5 | 28.5 | 149.0 |
3H-3, 75 | 137.55 | 135.69 | 1.172 | 67.0 | 25.0 | 92.0 |
4H-3, 75 | 147.05 | 145.19 | 1.114 | 79.0 | 26.0 | 105.0 |
4H-3, 75 | 147.05 | 145.19 | 1.098 | 73.0 | 25.0 | 98.0 |
5H-3, 75 | 156.55 | 154.69 | 1.141 | 100.0 | 25.0 | 125.0 |
5H-3, 75 | 156.55 | 154.69 | 1.170 | 56.0 | 25.0 | 81.0 |
6X-2, 75 | 164.55 | 162.69 | 1.095 | 101.5 | 25.5 | 127.0 |
6X-2, 75 | 164.55 | 162.69 | 1.120 | 67.0 | 25.0 | 92.0 |
7X-3, 75 | 169.42 | 167.56 | 1.168 | 97.0 | 25.0 | 122.0 |
7X-3, 75 | 169.42 | 167.56 | 1.204 | 50.0 | 25.0 | 75.0 |
8X-3, 75 | 179.35 | 179.35 | 1.226 | 43.5 | 28.5 | 72.0 |
8X-3, 75 | 179.35 | 179.35 | 1.156 | 87.5 | 25.0 | 112.5 |
9X-3, 75 | 188.95 | 188.95 | 1.092 | 41.5 | 25.0 | 66.5 |
9X-3, 75 | 188.95 | 188.95 | 1.104 | 65.5 | 25.0 | 90.5 |
10X-3, 75 | 198.55 | 198.55 | 1.149 | 59.5 | 28.5 | 88.0 |
10X-3, 75 | 198.55 | 198.55 | 1.104 | 121.5 | 26.5 | 148.0 |
11X-3, 75 | 207.62 | 207.62 | 1.078 | 59.0 | 25.0 | 84.0 |
11X-3, 75 | 207.62 | 207.62 | 1.035 | 113.0 | 25.0 | 138.0 |
13X-3, 75 | 227.45 | 227.45 | 1.187 | 77.0 | 25.0 | 102.0 |
13X-3, 75 | 227.45 | 227.45 | 1.201 | 36.0 | 25.0 | 61.0 |
Notes: TC = thermal conductivity. Start, Length, and End refer to the interval of the time-temperature series used for the determination of thermal conductivity. This table is also available in ASCII format in the TABLES directory.