Table T12. Thermal conductivity values for Site 1140.
 
Core, section,
interval (cm)
Depth
(mbsf)
Thermal conductivity
(W/[m·K])
183-1140A-    
2R-3, 75 13.25 0.67
3R-1, 75 19.35 0.82
4R-2, 24 29.64 0.90
6R-2, 60 48.60 0.92
7R-2, 28 57.38 0.96
9R-1, 75 74.45 0.93
10R-1, 75 84.05 0.90
13R-1, 75 112.95 0.96
14R-2, 75 123.95 0.87
15R-3, 75 141.75 0.81
16R-1, 75 151.30 0.79
17R-1, 60 164.15 0.96
18R-3, 85 173.65 0.98
19R-3, 75 183.25 0.91
20R-3, 75 192.85 0.95
22R-3, 75 202.45 0.97
23R-2, 75 210.55 0.85
25R-6, 50-64 235.09 1.71
26R-2, 60-78 239.18 1.76
27R-1, 118-140 240.59 1.51
27R-3, 45-66 242.55 2.06
28R-3, 112-124 250.53 1.49
31R-1, 95-107 271.51 1.47
32R-2, 32-50 277.11 1.78
33R-2, 33-47 286.42 1.61
33R-3, 10-25 287.56 1.55
34R-1, 111-122 295.27 1.58
34R-2, 92-109 296.61 1.49
34R-4, 70-80 298.95 2.15
35R-1, 1-15 303.58 1.68
35R-2, 60-70 305.62 1.58
36R-1, 122-137 314.00 1.71
36R-4, 30-43 317.28 1.68
37R-1, 18-40 317.59 1.72
37R-4, 12-19 320.64 1.73

Notes: Depth = bottom depth of sample interval. This table is also available in ASCII format.