Table T18. Summary of in situ temperature measurements at Site 1151.
Hole, core | Depth
(mbsf) |
Tool | Equilibrium temperature (°C) |
Comments |
---|---|---|---|---|
186- |
|
|||
1151C |
Mudline
|
APC |
1.96 ± 0.1
|
|
1151C-4H | 30.70 | APC |
2.93 ± 0.1
|
|
1151A-18R | 228.10 | DVTP |
—
|
Bad data |
1151A-20R | 247.30 | DVTP |
—
|
Bad data |
1150A-33R | 372.90 | DVTP |
15.38 ± 0.1
|
Note: APC = APC (advanced hydraulic piston core) Adara temperature tool, DVTP = Davis-Villinger temperature probe.