Initial Reports Volume 188 Chapter 4. Table 9. Full- and half-space needle measurements of thermal conductivity, Site 1166. Thermal conductivity measurements Core, section, interval (cm) Depth (mbsf) Type Probe number Reading 1 Reading 2 Reading 3 Reading 4 Average (W/[m x deg C]) 188-1166A- 3R-1, 75 20.55 Full V00694 1.311 1.370 1.338 1.340 9R-1, 47 75.47 Full V00694 0.979 0.979 9R-1, 55 75.55 Full V00694 1.575 1.516 1.649 1.580 11R-1, 60 94.60 Full V00694 1.296 1.435 1.571 1.434 11R-1, 60 94.60 Full V00694 1.582 1.472 1.453 1.502 12R-1, 119 104.89 Full V00694 1.554 1.567 1.605 1.575 13R-2, 91 115.71 Full V00694 1.294 1.264 1.398 1.319 13R-2, 55 115.35 Full V00694 1.032 1.009 0.097 0.713 14R-4, 75 128.25 Full V00694 1.559 1.682 1.624 1.622 15R-2, 85 134.90 Full V00694 1.123 1.282 1.143 1.183 16R-3, 83 146.03 Half H19608 0.793 1.023 0.970 0.964 0.938 17R-2, 52 153.42 Half H19608 2.188 1.987 2.383 2.079 2.159