Table T4. Available command set in the CRM, OBH, and SAM.

Command
Definition
CRM available command set:
ok-1 Enable FORTH vocabulary
.bauds List baud-rate settings for each serial port
streams? List all streams and port numbers being received in format: StreamID SystemID Port#
open sysID strID Open other system terminal by pass-thru
(head 4 characters)
close Close the pass-thru terminal link
.ids Show what instrument(s) are currently being talked to
time set-rtc Set real-time clock for time stamp in format: yy mm dd hh mm ss
@rtc.rtc Fetch real-time clock setting and print
port# baud# baud Change baud rate
id set-id
re-sync on Resynchronize clock to Global Positioning System
auto-trim Trim the clock start
interval on Disable auto-calibration
n install Add the channel for control and monitoring
n remove Remove control and monitoring
n disable Switch off the channel and prevent further operation; monitoring is not affected
n enable Reenable switching on
n power-up Switch on the channel—if not disabled
n power-down Switch off the channel
time wake-up Set start time in format: mm dd hh mm
sleep Switch off the system using watch-dog reset
.limit Display setting in the units shown in the status block
vl vh ch set-limits Set limits of power control; vl = switch off voltage, vh = high limit, and ch = channel of PDM
.st Status reading from power distribution module
.boot Display last reboot
run-hours? Show time since last boot
.mean Show mean voltage of power supply
running? Show running status
bad-match ? Display how many more consistent clock measurements are necessary to resynchronize
trm-trim ? Display a number for clock trim in the backup memory in the power distribution module
phase Show the clock status
.pwm Show the clock offset and drift
reminder Set the clock into timer mode (set a maximum off time of 10 min)
manual Start the system in timer mode
8 watch +! Switch on monitoring
-8 watch +! Switch off monitoring
ch remove Stop switching and monitoring of the channel (e.g., pmd)
ch disable Stop switching only—status will still be displayed
o/p ? This should show zero (i.e., no task currently outputting to the display/status)
0 0 o/p 2! Manually reset the semaphore
set-clock Set backup real-time clock
rtc>sam Set real-time clock into internal clock (MEG, SAM)
.int Display internal clock
master-sync Set internal clock (and backup real-time clock) to the RTM time
2400 /sci2 Set baud rate of the GPS serial port to 2400 bps for accessing the RTM
4800 /sci2 Restore baud rate for GPS connection
rtm-open Enable access to the RTM module
rtm-close Disable access to the RTM module
+1ppm Change the frequency of the RTM (precision clock)
-1ppm Change the frequency of the RTM (precision clock)
cancel Restore the module to normal state using the calculated trim value
n faster Change the RTM frequency by n ppm
n slower Change the RTM frequency by n ppm
n enable Request n channel makes enabled (for a shutdown channel)
Ref-clk +time Increment internal clock by 1 s
-1 ref-clk 2+ +! Decrement internal clock by 1 s
Re-sync on Enable resync to reference (resync requires 15 min of mismatch)
Auto-trim on Allow trimming of real-time module to reference time
Rtm-trim ? Report total trim value
1 sync-on
n gps-type n; 2-GARMIN, 3-Stream sync
time-ref ? Restart synchronization
configuration show
sync-src ? See settings by GPS-type commands
.ext Show external clock
/uarts Initialize UARTS
n activate Enable serial port #n
n rate baud re-boot Change baud rate (n = port #, rate = baud rate)
OBH available command set:
date d-day Set deploy date in format: day month year
.d-day Show deploy date setting
Mpos n dump Hex dump first n mass positions (each 2 bytes)
Mpos ? Request mass position of Z
Mpos 2 + ? Request mass position of N-S
Mpos 4 + ? Request mass position of E-W
Masses? Show mass positions continuously (type any key to stop)
.soh Request ocean borehole seismometer health status
SAM available command set:
2 ~protect Disarm protection of the flash memory
save-cmos Save CMOS memory in EEPROM
dir Display directory of the HDD records
chunk? Check number of memory chip installed; 1 chip = 4 MB
target#? Show current target HDD
n target Set current HDD.flash
chk-disc Spin-up current disk
stop-unit Spin down
Reset-disc Initialize current disk
Next-target Increase SCSI ID of HDD
0 erase-card Erase the whole card
0 erase-chip Erase specified chip: 0-15, 4 MB each
/flash# Reset the pointers to 0|0
2 /chunk Change number of chips for buffering (2-14); maximum is 14 to allow time for disk operation
Disc-off Spin-down HDD
2 ~protect save-cmos Copy entire CMOS to EEPROM
.d-day Show deploy date setting

Notes: CRM = combiner/repeater module, OBH = ocean borehole seismometer, SAM = storage acquisition module, GPS = Global Positioning System, MEG = multiple-access expandable gateway, RTM = real-time clock, HDD = hard disk drive. Italics denote variables in the command string.