Table T11. ICP-AES analyses of the composite sample from Hole 1189A*.
 
Analyte
Result
Detection
limit
Oxide (wt%):

TiO2 0.504
Al2O3 12.87
Fe2O3 8.75
MnO 0.020
MgO 1.83
CaO 1.59
Na2O 1.90
K2O 2.21
P2O5 0.167
S(tot) 5.95
Trace element (ppm):
Li BD 5
Be BD 2
Sc 10
V 41
Cr 12
Co 28
Ni BD 10
Cu 2610
Zn 34
As BD 20
Sr 140
Y 20
Zr 91
Mo BD 5
Ag BD 5
Sb BD 20
Ba 497
La 10
Yb 3 2
Lu BD 5
Pb BD 50
Au (ppb) BD 200

Notes: ICP-AES = inductively coupled plasma-atomic emission spectroscopy. * = sample sent to Commonwealth and Industrial Research Organization (CSIRO) for midcruise shore-based analyses (shipment number 1189A-(1); CSIRO number 142646D). † = contamination from tungsten carbide mill. BD = below detection limit. Analyst: L. Dotter, CSIRO, Australia.