Table T9. Total sulfur and water measurements on powdered samples used for ICP-AES and XRD analysis, Hole 1189A.
 
Core, section,
interval (cm)
Curated
depth
(mbsf)
TS unignited
(wt%)
TS
ignited*
(wt%)
TS
ignited
(wt%)
H2O+
unignited
(%)
193-1189A-




1R-1, 0-4 0.02 0.04 BD ND 1.35
2R-1, 34-35 10.04 0.51 ND ND 2.44
2R-1, 77-78 10.47 9.39 ND ND 2.34
2R-1, 113-115 10.83 2.66 1.79 0.41 2.69
3R-1, 6-10 19.46 0.83 0.03 ND 1.71
3R1, 20-22 19.60 1.22 ND BD 3.27
3R-1, 59-63 19.99 9.15 5.99 1.20 3.00
3R-1, 70-73 20.10 4.89 0.16 ND 1.67
4R1, 17-20 29.27 2.42 ND 0.02 3.13
4R-1, 21-24 29.31 2.73 0.24 ND 2.74
5R-1, 14-16 38.94 4.50 0.56 ND 3.92
7R-1, 27-28 58.57 4.42 BD ND 1.68
7R-1, 58-59 58.88 7.61 ND ND 2.07
7R-1, 95-96 59.25 1.11 ND ND 1.37
8R-1, 31-32 68.31 3.05 ND ND 1.62
8R-1, 42-44 68.42 2.89 BD ND 1.59
8R-1, 90-92 68.90 3.70 BD ND 1.17
8R-1, 113-114 69.13 2.12 ND ND 1.42
9R-1, 16-17 77.86 7.26 ND ND 1.24
10R-1, 0-1 87.30 2.71 ND ND 1.83
10R-1, 50-51 87.80 4.41 ND ND 2.36
11R-1, 37-38 97.27 3.12 ND ND 3.19
12R-1, 69-70 107.17 2.86 0.14 ND 2.65
13R-1, 24-33 116.34 6.19 0.36 ND 7.00

Notes: TS = total sulfur. * = powder ignited at 600°C for 6 hr and then at 1050°C for 1 hr, † = powder ignited at 600°C for 6 hr and then at 1050°C for 4 hr. Detection limit = 0.01. Instrument precision = ±0.04%. ND = not determined. BD = below detection.