Table T7. Measurements made by wireline tool strings.
Tool string* Tool Measurement Sampling interval
(cm)
Approximate vertical resolution
(cm)
Triple combination HNGS Spectral gamma ray 15 51

APS Porosity 5 and 15 43

HLDS Bulk density 2.5 and 15 38/46

DIT Resistivity 15 200/150/76

MGT** Gamma ray 15 15
Formation MicroScanner (FMS)-sonic combination NGT Spectral gamma ray 15 46

GPIT Tool orientation 0.25 and 15 NA

FMS Microresistivity 0.25 0.5

DSI Acoustic velocity 15 107





GHMT NGT Spectral gamma ray 15 46

SUMS Susceptibility 5 and 15 35

NMRS Total field 5 and 15 45

Notes: * = all tool and tool string names (except the TAP and MGT tools) are trademarks of Schlumberger. † = for additional information about tool physics and use consult ODP Logging Services at http://www.ldeo.columbia.edu/BRG/ODP. ‡ = see Table T8 for explanations of acronyms used to describe tool strings and tools. ** = not included in each logging run. NA = not applicable.