Table T3. Summary of Fugro Percussion Corer operations, Leg 201.
Run
Core
Date
(Mar 2002)
Depth
(mbsf)
Comments

201-


1 1227A-16M 1 131.1 A few centimeters of gravel recovered. Autoclave not under pressure due to gravel in valve.
2 1227E-4M 2 25.8 40 cm sandy clay recovered, data logger failed, no pressure measured.
3 1228A-13M 4 109.4 50 cm of gravel recovered, core liner collapsed, seals damaged, no pressure retained.
4 1228B-7M 6 54.3 42 cm of clay recovered, valve stuck open, seals damaged, pawls inside housing damaged, no pressure retained.
5 1228E-2M 6 7.3 65 cm of clay recovered, valve stuck open, seals damaged, no pressure retained.
6 1229A-20M 8 174.4 40 cm of gravel with some clay, valve stuck open, seals damaged, no pressure retained.
7 1229B-4M 8 24.4 Inner barrel did not fully retract, jammed due to previous seal failure, previously damaged pawls in housing sheared off, damaged beyond repair at sea, no core recovered, no pressure retained.