Table T12. Downhole temperature measurement summary, Holes 1226A, 1226B, and 1226E.
Depth
(mbsf)
Tool
Measurement
location
Thermal
conductivity
(W/[m·K])
Temperature
(°C)
0.0 Adara Seafloor 1226A-1H 1.72
0.0 Adara Seafloor 1226B-2H 1.77
45.6 Adara B Core 1226E-5H 0.81 4.56
61.4 Adara B Core 1226B-7H 0.74 5.65
74.1 Adara B Core 1226E-8H 0.77 6.35
89.9 Adara B Core 1226B-10H 0.77 7.30
112.1 Adara B Core 1226E-12H 0.82 8.63
118.4 Adara B Core 1226B-13H 0.87 9.04
146.9 Adara B Core 1226B-16H 0.92 10.61
194.4 Adara B Core 1226B-21H 0.97 12.88
262.4 DVTP T Core 1226B-29H 0.81 16.83
307.0 DVTP T Core 1226E-19H 0.71 19.44
310.0 DVTP T Core 1226B-34X 0.71 21.20
358.4 DVTP T Core 1226B-39X 0.96 22.26
400.0 DVTP T Core 1226E-24X 0.83 23.70
422.0 0.85* 25.88

Notes: DVTP = Davis-Villinger Temperature Probe. B = bottom of core, T = top of core. — = not applicable. * = average thermal conductivity. † = projected temperature at base of hole. The last line shows the temperature extrapolated to basement using linear fit in Figure F28 and the mean thermal conductivity computed from data plotted in Figure F26A.