Table T9. Downhole temperature measurement summary, Hole 1228A.
Depth
(mbsf)
Tool
Measurement
location
Thermal
conductivity (W/[m·K])
Temperature
(°C)
Assessment
0.0 Adara Seafloor, T Core 201-1228E-1H 13.7 Possible annual variation
0.0


12.5
24.8 Adara Core 112-680C-3H 13.3
34.0 Adara Core 112-680B-4H 13.8
42.0 DVTP B Core 201-1228A-5H 15.8 Curve wrong shape; value too high
80.9 DVTP 2 B Core 201-1228A-9H 0.93 15.2 Good
137.9 DVTP B Core 201-1228A-16H No decay profile; large oscillations
194.9 DVTP 1 B Core 201-1228A-22H 1.13 19.1 Good
200.9 0.96* 19.3

Notes: DVTP = Davis-Villinger Temperature Probe. T = top of core, B = bottom of core. — = not applicable. * = average thermal conductivity, † = projected temperatures at seafloor and base of hole. The last line shows the temperature extrapolated to basement using linear fit in Figure F20 and the mean thermal conductivity computed from data plotted in Figure F18A.