Table T19. Temperature measurements, Holes 1245B, 1245C, and 1245E.
Site, hole,
core
Depth
(mbsf)
Temperature
(°C)
Thermal
conductivity
(W/[m·K])
Tool ID
204-1244B-



4H 35.1 6.15 0.88 12
204-1244C-



7H 62.5 7.77 0.97 12
9H 81.5 9.13 0.92 12
12H 110.0 10.71 0.93 12
7H-8H 62.5 9.00 3
19X-20X 149.4 13.02 3
204-1244E-



1H 00.0 3.76 1.20 11
5H 39.2 5.85 0.87 11
7H 50.7 6.39 0.99 11
9H 62.1 7.48 0.93 11
13H 92.6 9.21 0.94 11
17H 123.1 11.03 0.93 11
8Y-9H 52.6 7.04 2
19X-BOH 140.7 12.56 2

Notes: For measurements made with the APCT, the tool was at the core catcher of the core barrel for the core cited. DVTPP measurements were made in between the two cores cited. Temperatures represent the equilibrium temperature determined, as discussed in "Thermal Conductivity" in "Physical Properties" in the "Explanatory Notes" chapter, assuming the thermal conductivity given in the table, which is the average of the nine measurements taken in the adjacent core. No thermal conductivity values are given for the DVTPP data because in situ temperatures were measured directly from the data after the tool had been in the formation for at least 30 min and equilibrium appeared to have been reached. BOH = bottom of hole. ID = identification.