Hole, core
|
Depth
(mbsf) |
Temperature
(°C) |
Thermal
conductivity (W/[m·K]) |
Tool ID
|
---|---|---|---|---|
204- |
|
|
|
|
1245C-1H | 00.0 | 3.82 | 1.20 | 12 |
1245B-4H | 38.0 | 5.98 | 1.03 | 12 |
1245B-7H | 66.5 | 8.09 | 0.87 | 12 |
1245B-10H | 95.0 | 8.95 | 1.00 | 12 |
1245B-13H | 122.7 | 10.71 | 1.01 | 12 |
1245B-14H | 127.8 | 11.00 | 1.03 | 12 |
1245C-24H | 186.6 | 13.93 | 1.00 | 12 |
1245C-25H | 191.1 | 14.52 | 1.00 | 12 |
1245C-26H | 195.9 | 14.71 | 1.04 | 12 |
1245C-28H | 200.7 | 14.94 | 1.00 | 12 |
1245B-20X-21X | 176.6 | — | — | 2 |
1245B-27X-28X | 243.0 | — | — | 2 |
1245B-39X-40X | 348.9 | — | — | 2 |
Notes: APCT measurements were made at the core catcher of the core listed. For APCT measurements, thermal conductivity represents the average of the nine measurements taken in the adjacent core. Measurements for two core numbers are given (e.g. 204-1245B-20X-21X) were made with the DVTP between these two cores. At this site, none of the DVTP deployments yielded temperature time series indicative of a reliable measurement. ID = identification.