Tool
|
Output
|
Tool name/explanation of output
|
Unit
|
---|---|---|---|
APS |
|
Accelerator Porosity Sonde |
|
|
APLC | Near array porosity (limestone calibrated) | % |
|
SIGF | Formation capture cross section (f) | Capture units |
|
STOF | Tool standoff (computed distance from borehole wall) | in |
DIT |
|
Dual Induction Tool |
|
|
IDPH | Deep induction resistivity | m |
|
IMPH | Medium induction resistivity | m |
|
SFLU | Spherically focused resistivity | m |
DSI |
|
Dipole Sonic Imager |
|
|
DTCO | Compressional wave delay time (t) | ms/ft |
|
DTSM | Shear wave delay time (t) | ms/ft |
|
DTST | Stoneley wave delay time (t) | ms/ft |
FMS |
|
Formation MicroScanner |
|
|
C1, C2 | Orthogonal hole diameters | in |
|
P1AZ | Pad 1 azimuth | Degrees |
|
|
Spatially oriented resistivity images of borehole wall |
|
GPIT |
|
General Purpose Inclinometer Tool |
|
|
DEVI | Hole deviation | Degrees |
|
HAZI | Hole azimuth | Degrees |
|
Fx, Fy , Fz | Earth's magnetic field (three orthogonal components) | Degrees |
|
Ax, Ay , Az | Acceleration (three orthogonal components) | m/s2 |
HLDS |
|
Hostile Environment Litho-Density Sonde |
|
|
RHOM | Bulk density | g/cm3 |
|
PEF | Photoelectric effect | b/e– |
|
LCAL | Caliper (measure of borehole diameter) | in |
|
DRH | Bulk density correction | g/cm3 |
HNGS |
|
Hostile Environment Gamma Ray Sonde |
|
|
HSGR | Standard (total) gamma ray | gAPI |
|
HCGR | Computed gamma ray (HSGR minus uranium contribution) | gAPI |
|
HFK | Potassium | wt% |
|
HTHO | Thorium | ppm |
|
HURA | Uranium | ppm |
|
HBHK | Borehole potassium | dec. fract. |
MGT |
|
Multi-Sensor Spectral Gamma Ray Tool |
|
|
GR | Total gamma ray | gAPI |
|
POTA | Potassium | wt% |
|
THOR | Thorium | ppm |
|
URAN | Uranium | ppm |
SGT |
|
Scintillation Gamma Ray Tool |
|
|
ECGR | Environmentally corrected gamma ray | gAPI |
TAP |
|
Temperature/Acceleration/Pressure tool | °C, m/s2, psi |
WST-3* |
|
Well Seismic Tool (3 components) |
|
|
|
Acoustic arrival times | ms |
Notes: All tool and tool string names (except the TAP and MGT) are trademarks of Schlumberger. For the complete list of acronyms used in the ODP and for additional information about tool physics and use consult ODP Logging Services at www.ldeo.columbia.edu/BRG/ODP. * = not included on every operation.