201-
|
|
|
|
|
1227A-16M
|
|
131.1
|
A few centimeters of gravel recovered. Autoclave not under pressure due to gravel in valve.
|
|
1227E-4M
|
|
25.8
|
40 cm sandy clay recovered, datalogger failed, no pressure measured.
|
|
1228A-13M
|
|
109.4
|
50 cm of gravel recovered, core liner collapsed, seals damaged, no pressure retained.
|
|
1228B-7M
|
|
54.3
|
42 cm of clay recovered, valve stuck open, seals damaged, pawls inside housing damaged, no pressure retained.
|
|
1228E-2M
|
|
7.3
|
65 cm of clay recovered, valve stuck open, seals damaged, no pressure retained.
|
|
1229A-20M
|
|
174.4
|
40 cm of gravel with some clay, valve stuck open, seals damaged, no pressure retained.
|
|
1229B-4M
|
|
24.4
|
Inner barrel did not fully retract, jammed due to previous seal failure, previously damaged pawls in housing sheared off, damaged beyond repair at sea, no core recovered, no pressure retained.
|